• Home
  • Products
  • Product Configurator
  • CRYO CHAMBER GUIDE
  • SUPPORT
  • Contact
  • Select another country or territory to see content for your region.

    For more information on the CRYO XC™ Plus, CRYO XC™ & CRYO LC visit our product pages

    Minimum
    Recommended

    15 m2   |   160 sqft
    25 m2   |   270 sqft

    Minimum
    Recommended

    20 m2   |   200 sqft
    25 m2   |   270 sqft

    Standard Tank (Dewar)

    *Two dewar vessels are included with the non-pressurized system.

    50 L (Non-Pressurized)

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    4 to 7 Liters*

    Max 4000W; Session 1000W

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    Low capacity tanks

    Standard capacity tanks

    High capacity tanks

    Optimum Pressure

    *Pressurized tanks are not included.

    70 L, 160 L

    180 L, 240 L, 320 L, 350 L

    500 L, 750 L, 1000 L

    1,5 to 2,5 BAR  |  22 to 37 psi

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    5 to 8 Liters*

    Max 4000W; Session 1000W;

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    SystemsPressurized | Non-Pressurized

    Pressurized system

    Non-Pressurized system

    PRESSURIZED

    Non-PRESSURIZED

    Description

    The CRYO XC™ Pressurized system uses pressurized tanks and vessels for the storage and supply of liquid nitrogen.

    During operation, liquid nitrogen is supplied into the system under pressure that is maintained inside the storage vessel.

    Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.
     

    The CRYO XC™ Non-Pressurized system uses non-pressurized vessels or dewars for the storage and supply of liquid nitrogen.

    During operation, liquid nitrogen is transferred into the system with the help of pressure created by the cryotherapy unit.

    Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.

    AVAILABILITY

    CRYO XC™ Plus
    CRYO XC™

    CRYO XC™ Plus
    CRYO XC™

    MEDIUM

    The Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

    The Non-Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

    Storage

    Low capacity tanks

    Standard capacity tanks

    High capacity tanks

    Optimum Pressure

    *Pressurized tanks are not included.

    70 L, 160 L

    180 L, 240 L, 320 L, 350 L

    500 L, 750 L, 1000 L

    1,5 to 2,5 BAR  |  22 to 37 psi

    Standard Tank (Dewar)

    *Two dewar vessels are included with the non-pressurized system.

    50 L (Non-Pressurized)

    CONSUMPTION

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    5 to 8 Liters*

    Max 4000W; Session 1000W;

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    4 to 7 Liters*

    Max 4000W; Session 1000W

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    ROOM REQUIREMENTS

    Minimum
    Recommended

    20 m2   |   200 sqft
    25 m2   |   270 sqft

    The pressurized system requires barrier free access to the supply zone. The lightest pressurized vessels/cylinders weigh  approximately 150 Kg/ 330 Lbs when empty.

    The recommended ceiling height is 240 cm / 8 ft

    For more info go to Room Requirements

    Minimum
    Recommended

    15 m2   |   160 sqft
    25 m2   |   270 sqft

    The non-pressurized system allows for easier access from the supply zone to the cryotherapy unit. The tare weight of the dewar vessel is 17 kg / 25 Lbs and 65 Kg / 130 Lbs when full. These vessels can be carried by hand for refills.

    The recommended ceiling height is 240 cm / 8 ft

    For more info go to Room Requirements

    SUITABLE FOR

    High capacity & high footfall locations. Wellness/Recovery centers, sports organizations, fitness centers, training facilities, rehabilitation facilities, medical facilities/clinics

    Cryotherapy startups, wellness/recovery centers, spas, sports organizations, fitness centers, training facilities, beauty centers, home & private use, exclusive social clubs

    APPROVAL

    The Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

    The Non-Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

    WELCOME TO THE CONFIGURATOR

    What is the purpose of the Configurator?

    1. Learn more about our products, ranging from systems, color options and orientation to dimensions, packaging, warranties and the order process.
    2. Personalize the CRYO XC™ to fit your needs and your brand.
    3. Save time by getting a more precise quotation for our equipment and services.

    Terms of Use

    1. All information provided in the Configurator is for informational purposes only.
    2. Submitting a form through the Configurator does not give the user any obligation to purchase selected products or services.
    3. The Configurator is intended to guide the user through the options and provide the user with more detailed information.
    4. All product customization and service options are subject to availability.

    GO TO NEXT STEP

    CRYO XC™ Plus & CRYO XC™

    Model features

    Cryo XCTM PlusCryo XCTM
    MODELS Cryo XCTM Cryo XCTM Plus
    Description
    The CRYO XC™ is CRYONiQ's best-seller. Designed to offer a balanced cryotherapy session and maximum exposure to extreme temperatures.
    The CRYO XC™ Plus is CRYONiQ's flagship cryotherapy chamber which offers an enhanced cryotherapy experience for clients and operators with additional safety and design features.
    Features
    21,5" Touchscreen - Control Panel
    15" Multimedia/Info Screen
    Thermal Contrast Cryotherapy 
    Adaptable Orientation
    Lift
    Deflectors
    Active Drying System
    Session Tracker
    Remote Diagnostics
    Safety Relief Vent
    Exhaust Fan
    Oxygen Monitoring
    Door Sensor
    Humidity Tracking
    Pressure Tracking
    Tremor Emergency Stop
    Heart Rate Monitor

    Systems

    Pressurized System
    Available
    Compare
    Available
    Compare
    Non-Pressurized System
    Available
    Compare
    Available
    Compare

    SESSION TEMPERATURE (Exclusions Apply)

    Temperature Range (Recommended)
    170°F to -200°F
    -110°C to -140°C
    -170°F to -200°F
    -110°C to -140°C
    Temperature Range (Expanded)
    -170°F to -240°F
    -110°C to -160°C
    -170°F to -240°F
    -110°C to -160°C

    STORAGE TANKS

    Pressurized System
    Tanks not included
    Tanks not included
    Non-Pressurized System
    2x 50 liter vessel included
    2x 50 liter vessel included

    LN2 CONSUMPTION 

    Pressurized System
    5 - 8 liters (LN2)
    5 - 8 liters (LN2)
    Non-Pressurized System
    4 - 7 liters (LN2)
    4 - 7 liters (LN2)
    Precool
    2 - 4 Liters (LN2)
    2 - 4 Liters (LN2)

    ELECTRICAL SPECIFICATION

    Outlet Voltage
    230V
    230V
    Frequency
    50 Hz
    50 Hz
    Amperes (Amps)
    min. 16 A
    min. 16 A
    Power Usage
    Max: 4000W
    Idle: 140W
    Session: 1000W
    Drying: 3400W
    Max: 4000W
    Idle: 140W
    Session: 1000W
    Drying: 3400W

    Certification

    CE Mark
    FDA 513g Non-Medical Device

    LEAD TIME

    New & Made-To-Order
    4 to 6 weeks from valid order
    4 to 6 weeks from valid order
    Existing Inventory | Stock Items
    1 to 2 weeks from valid order
    1 to 2 weeks from valid order
    Pre-Owned Inventory
    1 to 2 weeks from valid order
    1 to 2 weeks from valid order
    Express Delivery
    Faster Delivery of Made-To-Order Equipment
    Faster Delivery of Made-To-Order Equipment

    Warranty

    2 Year Limited Service Warranty
    2 Year Limited Parts Warranty
    3 Year Limited Service Warranty
    Available
    Available
    3 Year Limited Parts Warranty
    Available
    Extended Warranty
    Available
    Available

    SERVICES (Exclusions Apply)

    Door to door delivery
    On-Site Install
    On-Site Operator Training
    24/7 Tech Support
    First LN2 Fill for Operator Training*
    Risk Assessment (Remote)

    PROJECT ASSISTANCE (Exclusions Apply)

    LN2 Supplier Sourcing
    Available
    Available
    Financing Options | Lease Options
    Available
    Available
    Insurance Options
    Available
    Available
    Safety Regulations | Risk Assessment
    Available
    Available
    Operation Guidelines
    Available
    Available



    Cryo XCTM

    CRYO XC™ Cryocabin in anthracite grayCRYO XC™ Plus Cryocabin in blackCRYO XC™ Cryo machine in blueCRYO XC™ Cryotherapy unit in grayCRYO XC™ Cryotherapy unit in white

    Advanced

    Safety Features

    2 Available

    2 Available

    Systems

    Thermal Contrast

    Cryotherapy

    4 Integrated

    Safety Features

    10+ Unique

    10+

    Features

    Thermal Contrast

    Cryotherapy

    10 Integrated

    Safety Features

    15+ Unique

    15+

    Features

    Thermal Contrast

    Cryotherapy

    Minimum
    Recommended

    15 m2   |   160 sqft
    25 m2   |   270 sqft

    Minimum
    Recommended

    20 m2   |   200 sqft
    25 m2   |   270 sqft

    Standard Tank (Dewar)

    *Two dewar vessels are included with the non-pressurized system.

    50 L (Non-Pressurized)

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    4 to 7 Liters*

    Max 4000W; Session 1000W

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    Low capacity tanks

    Standard capacity tanks

    High capacity tanks

    Optimum Pressure

    *Pressurized tanks are not included.

    70 L, 160 L

    180 L, 240 L, 320 L, 350 L

    500 L, 750 L, 1000 L

    1,5 to 2,5 BAR  |  22 to 37 psi

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    5 to 8 Liters*

    Max 4000W; Session 1000W;

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    SystemsPressurized | Non-Pressurized

    Pressurized system

    Non-Pressurized system

    PRESSURIZED

    Non-PRESSURIZED

    Description

    The CRYO XC™ Pressurized system uses pressurized tanks and vessels for the storage and supply of liquid nitrogen.

    During operation, liquid nitrogen is supplied into the system under pressure that is maintained inside the storage vessel.

    Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.
     

    The CRYO XC™ Non-Pressurized system uses non-pressurized vessels or dewars for the storage and supply of liquid nitrogen.

    During operation, liquid nitrogen is transferred into the system with the help of pressure created by the cryotherapy unit.

    Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.

    AVAILABILITY

    CRYO XC™ Plus
    CRYO XC™

    CRYO XC™ Plus
    CRYO XC™

    MEDIUM

    The Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

    The Non-Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

    Storage

    Low capacity tanks

    Standard capacity tanks

    High capacity tanks

    Optimum Pressure

    *Pressurized tanks are not included.

    70 L, 160 L

    180 L, 240 L, 320 L, 350 L

    500 L, 750 L, 1000 L

    1,5 to 2,5 BAR  |  22 to 37 psi

    Standard Tank (Dewar)

    *Two dewar vessels are included with the non-pressurized system.

    50 L (Non-Pressurized)

    CONSUMPTION

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    5 to 8 Liters*

    Max 4000W; Session 1000W;

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    4 to 7 Liters*

    Max 4000W; Session 1000W

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    ROOM REQUIREMENTS

    Minimum
    Recommended

    20 m2   |   200 sqft
    25 m2   |   270 sqft

    The pressurized system requires barrier free access to the supply zone. The lightest pressurized vessels/cylinders weigh  approximately 150 Kg/ 330 Lbs when empty.

    The recommended ceiling height is 240 cm / 8 ft

    For more info go to Room Requirements

    Minimum
    Recommended

    15 m2   |   160 sqft
    25 m2   |   270 sqft

    The non-pressurized system allows for easier access from the supply zone to the cryotherapy unit. The tare weight of the dewar vessel is 17 kg / 25 Lbs and 65 Kg / 130 Lbs when full. These vessels can be carried by hand for refills.

    The recommended ceiling height is 240 cm / 8 ft

    For more info go to Room Requirements

    SUITABLE FOR

    High capacity & high footfall locations. Wellness/Recovery centers, sports organizations, fitness centers, training facilities, rehabilitation facilities, medical facilities/clinics

    Cryotherapy startups, wellness/recovery centers, spas, sports organizations, fitness centers, training facilities, beauty centers, home & private use, exclusive social clubs

    APPROVAL

    The Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

    The Non-Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

    Lorem ipsum content

    Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec consectetur nisl ligula, ut suscipit massa dictum eu. Proin vulputate orci et fringilla sollicitudin. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Aenean porta dolor vel lacus molestie porttitor. Fusce lectus velit, tincidunt vel sapien in, mollis tempor ligula. Nam vitae mattis elit, ut commodo felis. Integer fermentum porta urna, vel faucibus turpis pellentesque nec. Interdum et malesuada fames ac ante ipsum primis in faucibus. Suspendisse potenti. Quisque ornare tincidunt purus. Integer eu nulla vel ipsum malesuada placerat. Quisque placerat finibus elit eu vestibulum.

    Capacity & Readiness

    CRYO XC™  |  Pressurized System

    The CRYO XC™ Pressurized System is suitable for:

    • High Capacity & Footfall locations.
    • Wellness / Recovery centers, Sports clubs, Fitness centers, Training centers & Rehabilitation facilities.

    The CRYO XC™ Pressurized System cryotherapy chamber runs on electric power while using liquid nitrogen to cool the cabin.
    For this system, Liquid Nitrogen is stored in pressurized/nitrogen tanks with various capacities available from 70 liters up to thousands of liters.
    Standard capacities of nitrogen tanks used for storage range from 160 - 350 liters.

    The system releases LN2 into the vapor mechanism at a pressure of 1,5 BAR | 22 psi up to the maximum pressure limit at 3 BAR | 43 psi.

    All pressurized/nitrogen tanks require regular deliveries of liquid nitrogen to operate.
    Unrestricted access is essential for the mobility of storage vessels and seamless deliveries into the facility.
    The standard consumption of the CRYO XC™ Pressurized System ranges between 4 - 8 liters  per session under regular conditions.

    Liquid Nitrogen Characteristics

    Liquid Nitrogen offers one of the most easily storable and usable coolants available to the general public.

    The CRYO XC™ uses liquid nitrogen as a coolant for its extremely cold properties that allow for a rapid cooldown & immediate thermal shock for the client.
    A cryotherapy chamber must be able to efficiently & safely process liquid nitrogen and fully transform it into a gas that is released into the cabin.
    Any loose liquid nitrogen that enters the client cabin can be potentially dangerous for the client. The possibility of such conditions must be prevented by the cryotherapy chamber.

    The abbreviation for Liquid Nitrogen is LN2 or LIN

    1 liter of LN2 = 0.8 Kg / 1.76 lbs
    1kg / 2.20 lbs of LN2 = 1.2349 liters

    Standard Consumption

    • The standard consumption of the CRYO XC™ is a result of an extensive series of tests conducted in rigorous work environments and conditions.          
    • Different settings and conditions may result in different outcomes of consumption.

    Consumption of LN2 in a cryotherapy chamber is mostly determined by the physical settings & equipment used:

    • Intensity of session (Temperature Settings on the CRYO XC™)
    • Length of Session (Time Settings on the CRYO XC™)
    • Specification of Pressurized/Nitrogen tank (Internal Pressure of the tank)
    • Specification of Transfer Lines (Type of Transfer Hose)

     

    Besides the importance of physical settings & equipment:

    • The consumption of a cryotherapy chamber is also determined by scheduling & management of daily operation (Operator).  
    • Minimizing inactivity of the unit between sessions increases efficiency.

    Technical Considerations

    The main points to consider when deciding to buy a cryotherapy chamber.mption.

    • Consumption
      • Most open top cryotherapy chambers or cryosaunas available today offer similar levels of consumption.
      • Manufacturers may state consumption in liters per minutes.
      • Manufacturers may state consumption in Kg/Lbs, instead of the generally accepted standardin Liters/session.
    • Quality of Session
      • Balanced Temperature throughout cabin.
      • Realistic Temperature in cabin.
    • Safety
      • Safety Features
      • Safety Record
      • Certification
    • Build Quality
      • Material used
    • Level of Service
      • Technical Support
      • After-Warranty Care

    Capacity & Readiness

    CRYO XC™  |  Non-Pressurized System

    The CRYO XC™ Non-Pressurized System is suitable for:

    • Cryotherapy Start-Ups, Private Use
    • Wellness / Recovery centers, Spa’s, Sports clubs, Fitness centers, Training centers & Rehabilitation facilities, beauty centers, home use, private & exclusive settings

    The CRYO XC™ Non-Pressurized System cryotherapy chamber runs on electric power while using liquid nitrogen to cool the cabin.
    For this system, Liquid Nitrogen is stored in storage vessels called dewar vessels with a capacity of 50 liters each.
    The dewars used to supply the CRYO XC™ are exclusively supplied with CRYONiQ products and are not interchangeable.

    The system works by feeding LN2 into the vapor mechanism with rapid bursts of air, not requiring any containers under pressure.

    All dewar vessels require regular deliveries of liquid nitrogen to operate.
    Unrestricted access is essential for the mobility of storage vessels and seamless deliveries into the facility.
    The standard consumption of the CRYO XC™ Non-Pressurized System ranges between 3 - 7 liters  per session under regular conditions.

    Liquid Nitrogen Characteristics

    Liquid Nitrogen offers one of the most easily storable and usable coolants available to the general public.

    The CRYO XC™ uses liquid nitrogen as a coolant for its extremely cold properties that allow for a rapid cooldown & immediate thermal shock for the client.
    A cryotherapy chamber must be able to efficiently & safely process liquid nitrogen and fully transform it into a gas that is released into the cabin.
    Any loose liquid nitrogen that enters the client cabin can be potentially dangerous for the client. The possibility of such conditions must be prevented by the cryotherapy chamber.

    The abbreviation for Liquid Nitrogen is LN2 or LIN

    1 liter of LN2 = 0.8 Kg / 1.76 lbs
    1kg / 2.20 lbs of LN2 = 1.2349 liters

    Standard Consumption

    • The standard consumption of the CRYO XC™ is a result of an extensive series of tests conducted in rigorous work environments and conditions.          
    • Different settings and conditions may result in different outcomes of consumption.

    Consumption of LN2 in a cryotherapy chamber is mostly determined by the physical settings & equipment used:

    • Intensity of session (Temperature Settings on the CRYO XC™)
    • Length of Session (Time Settings on the CRYO XC™)
    • Specification of Pressurized/Nitrogen tank (Internal Pressure of the tank)
    • Specification of Transfer Lines (Type of Transfer Hose)

     

    Besides the importance of physical settings & equipment:

    • The consumption of a cryotherapy chamber is also determined by scheduling & management of daily operation (Operator).  
    • Minimizing inactivity of the unit between sessions increases efficiency.

    Technical Considerations

    The main points to consider when deciding to buy a cryotherapy chamber.mption.

    • Consumption
      • Most open top cryotherapy chambers or cryosaunas available today offer similar levels of consumption.
      • Manufacturers may state consumption in liters per minutes.
      • Manufacturers may state consumption in Kg/Lbs, instead of the generally accepted standardin Liters/session.
    • Quality of Session
      • Balanced Temperature throughout cabin.
      • Realistic Temperature in cabin.
    • Safety
      • Safety Features
      • Safety Record
      • Certification
    • Build Quality
      • Material used
    • Level of Service
      • Technical Support
      • After-Warranty Care

    Select Your System

    CRYO XC™ Cryocabin in anthracite grayCRYO XC™ Plus Cryocabin in blackCRYO XC™ Cryo machine in blueCRYO XC™ Cryotherapy unit in grayCRYO XC™ Cryotherapy unit in whiteCryotherapy machine with pressurized tank vesselCryotherapy machine with non-pressurized storage tankCryotherapy machine with pressurized tank vesselCryotherapy machine with non-pressurized storage tankCryotherapy machine with pressurized tank vesselCryotherapy machine with non-pressurized storage tankCryotherapy machine with pressurized tank vesselCryotherapy machine with non-pressurized storage tankCryotherapy machine with pressurized tank vesselCryotherapy machine with non-pressurized storage tank

    4 to 8 liters

    Consumption

    -150°C | -240°F

    Max Temperature

    Up to 15

    Clients p/h

    5 to 8 liters

    Consumption

    -150°C | -240°F

    Max Temperature

    Up to 15

    Clients p/h

    4 to 7 liters

    Consumption

    -150°C | -240°F

    Max Temperature

    Up to 15

    Clients p/h

    Customization & Specs

    CRYO XC™  Plus |  CRYO XC™

    Orientation

    Right-Oriented

    Right-Oriented units have the operator controls including the touchscreen, power button and the emergency stop button installed on the right hand side.

    The operator touchscreen installed on the right is default orientation for the CRYO XC™ Plus and CRYO XC™.

    Left-Oriented

    Left-Oriented units have the operator controls including the touchscreen, power button and the emergency stop button installed on the left hand side.

    Custom

    The Custom option allows the installation of the operator touchscreen on a solid surface separate from the CRYO XC™ Plus or CRYO XC™ such as walls, panels or the CRYONiQ stand. This option is designed to provide additional flexibility to the operator and clients. Maximum distance from the unit is 15 ft / 5 m.

    Custom orientation requires physical adjustments on the CRYO XC™/CRYO XC™ Plus and carries an additional fee. Get in touch with a CRYONiQ representative to find out more about the CRYONiQ Panel.

    CRYO XC™  Plus |  CRYO XC™

    Exterior Branding

    The outer shell of the CRYO XC™ Plus and CRYO XC™ can be personalized to your needs with branding and customized designs.
    Exterior branding requires submission of the selected graphic material. Exterior branding carries an additional fee.

    CRYO XC™  Plus |  CRYO XC™

    Interior Branding

    The interior of the CRYO XC™ Plus and CRYO XC™ can be personalized to your needs with customizable embroidery sewn into the fabric.
    Interior branding requires submission of the selected graphic material. CRYONiQ embroidery is included by default. Customization of the interior carries an additional fee.

    CRYO XC™  Plus |  CRYO XC™

    Physical Specs

    Height:

    7 ft 3 in
    222 cm

    Width:

    3 ft
    90 cm

    Depth (Closed):

    5 ft
    150 cm

    Depth (Closed):

    5 ft
    150 cm

    Span:

    5 ft
    150 cm

    Go to Physical Specs to learn more about the size of the cryotherapy chamber and how it fits into a room.

    CRYO XC™  Plus |  CRYO XC™

    Orientation

    Right-Oriented

    Right-Oriented units have the operator controls including the touchscreen, power button and the emergency stop button installed on the right hand side.

    The operator touchscreen installed on the right is default orientation for the CRYO XC™ Plus and CRYO XC™.

    Left-Oriented

    Left-Oriented units have the operator controls including the touchscreen, power button and the emergency stop button installed on the left hand side.

    Custom

    The Custom option allows the installation of the operator touchscreen on a solid surface separate from the CRYO XC™ Plus or CRYO XC™ such as walls, panels or the CRYONiQ stand. This option is designed to provide additional flexibility to the operator and clients. Maximum distance from the unit is 15 ft / 5 m.

    Custom orientation requires physical adjustments on the CRYO XC™/CRYO XC™ Plus and carries an additional fee. Get in touch with a CRYONiQ representative to find out more about the CRYONiQ Panel.

    CRYO XC™  Plus |  CRYO XC™

    Exterior Branding

    The outer shell of the CRYO XC™ Plus and CRYO XC™ can be personalized to your needs with branding and customized designs.
    Exterior branding requires submission of the selected graphic material. Exterior branding carries an additional fee.

    CRYO XC™  Plus |  CRYO XC™

    Interior Branding

    The interior of the CRYO XC™ Plus and CRYO XC™ can be personalized to your needs with customizable embroidery sewn into the fabric.
    Interior branding requires submission of the selected graphic material. CRYONiQ embroidery is included by default. Customization of the interior carries an additional fee.

    CRYO XC™  Plus |  CRYO XC™

    Physical Specs

    Height:

    7 ft 3 in
    222 cm

    Width:

    3 ft
    90 cm

    Depth (Closed):

    5 ft
    150 cm

    Depth (Closed):

    5 ft
    150 cm

    Span:

    5 ft
    150 cm

    Go to Physical Specs to learn more about the size of the cryotherapy chamber and how it fits into a room.

    Select Exterior Color

    CRYO XC™ Cryocabin in anthracite grayCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientationCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientationCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientationCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientationCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientationCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientation

    Flexible

    Orientation

    Customizable

    Branding*

    Smooth

    Install

    Select Interior Color

    Black interior of Cryotherapy chamberGray interior of Cryotherapy chamberLight Blue interior of Cryotherapy chamberBlue interior of Cryotherapy chamberGray interior of Cryotherapy chamber
    Black interior of Cryotherapy chamber CRYO XC™ PlusGray interior of Cryotherapy chamber CRYO XC™ PlusLight blue interior of Cryotherapy chamber CRYO XC™ PlusDark blue interior of Cryotherapy chamber CRYO XC™ PlusRed interior of Cryotherapy chamber CRYO XC™ Plus

    Aircraft Design

    Door Frames

    Customizable

    Embroidery*

    Cold Resistant

    Fabric

    Summary of additional options

    REQUEST PRICE

    Select options

    Scroll through our range of products and services and learn about our options.

    LN2 storage options include nitrogen tanks used for storing the required coolant for all CRYONiQ Whole Body Cryotherapy units and Localized Cryotherapy devices.
    These include pressurized tanks for the Pressurized system ranging from 120 liters, 180 liters, 240 liters and bulk storage tanks over 500 liters.
    For the Non-Pressurized System, we offer non-pressurized dewar vessels that carry up to 50 liters of LN2. Learn More
    Pressurized tanks for storage of liquid nitrogen
    LN2 Storage OptionsSelectDetails
    We offer a selection of stock and customized transfer hoses, pressure relief vents and other items necessary for the operation of nitrogen-cooled cryotherapy equipment.
    Get in touch with our team to find out more.
    Armored jacketed cryogenic transfer hose
    Cryogenic AccessoriesSelectDetails
    Wearing personal protective equipment (PPE) is one of the mandatory requirements while handling LN2, but also for the user inside the the whole body cryo chamber.
    Check out our range of items and find PPE for both equipment operators and daily cryotherapy users.
    Safety collar for cryotherapy treatments
    Operation Guidelines ensure that customers have a safe experience running and using our equipment starting from day one.
    Guidelines for daily operation can also improve efficiency of operation.
    Operation guidelines for cryotherapy center
    Operation GuidelinesSelectDetails
    Localized Cryotherapy, also called Spot Cryotherapy or a Cryofacial is a useful treatment for any location doing cryo or recovery.
    Localized Cryotherapy allows the operator to apply rapid cold treatments in a more coordinated way and target troublespots.
    Select to find out more about the CRYO LC.
    CRYO LC cryotherapy machine in center
    Local/Spot CryotherapySelectDetails
    CRYONiQ offers installation for of all new WBC equipment with a professional approach.
    Select this option to find out about the process or go to CRYO XC™ installation. Learn More
    Cryotherapy equipment install by CRYONiQ technician
    WBC InstallSelectDetails
    Get Insurance coverage for your cryotherapy business.
    Assistance with cryotherapy insurance may not be available in all territories. Learn More
    Cryotherapy insurance for business and home
    Cryotherapy InsuranceSelectDetails
    Electric Cryochambers offer a different experience to nitrogen cooled systems both in terms of service and customer experience.
    EC's operate on electricity and do not require LN2 to run.
    In some cases this can be an advantage especially for facilities that can't be serviced by an LN2 supplier.
    Select this option to get offers and information about electric cryotherapy chambers. Learn More
    Electric cryochamber and cryotherapy machine
    Electric CryochambersSelectDetails
    Hydromassage beds offer a relaxing experience to all users. Hydromassages are popular in office relaxation areas, but can be popular additions to businesses or for private use.
    Get in touch with our team to find out more about hydromassage beds.
    Wellsystem Hydromassage Bed
    Hydromassage BedsSelectDetails
    Find out if you can get nitrogen service in your area or get a quote on LN2.
    This service is intended for those looking to purchas CRYONiQ products for their business, training facilities or home gym. Learn More
    Liquid Nitrogen suppliers
    Gas RelationsSelectDetails
    Get ideas for your cryotherapy facilities from our selection of Furnishing options for Individuals & Businesses.
    Options include decoration, furniture, useful tools for operators and customers.
    Furnishing for waiting room in cryotherapy center
    FurnishingSelectDetails
    Operator training is an integral part of every equipment install. We offer annual training courses and refresher training on CRYONiQ products.
    Select to receive more information about CRYONiQ training or follow the link to Operator Training. Learn More
    Cryotherapy equipment training by CRYONiQ technician
    Operator TrainingSelectDetails
    Find out more about our technical support.
    Our additional service packages expand coverage for equipment both in and out of warranty and for equipment eligible for an extension of an existing warranty. Learn More
    Cryotherapy services and packages from CRYONiQ
    Service & WarrantySelectDetails
    Percussive therapy or vibration therapy apples a rapid burst of pressure on muscle tissue.
    Massage guns are used to treat muscle tension, soreness and cramps, and have proven to be a good choice for physiotherapists and sport enthusiasts that combines well with cryotherapy .
    Get in touch with our team to receive a list of options.
    Theragun massage gun
    Percussive TherapySelectDetails
    Compression therapy has become an established recovery modality for both pro athletes and everyday athletes.
    Get in touch with our team to receive a list of options.
    Normatec recovery gear and accessories
    Compression TherapySelectDetails
    As part of our service, we offer certified used cryotherapy machines. Select this option for additional information. Learn More
    Three cryosaunas next to each other
    Pre-Owned EquipmentSelectDetails
    Get assistance on setting up a new cryotherapy & recovery center or home gym.
    Project assistance includes a list of services such as bulk gas sourcing, cryotherapy insurance, assistance with safety & conformity, financing options, marketing, install & operator training, delivery & import. Learn More
    CRYONiQ cryotherapy center
    Project AssistanceSelectDetails
    Extend the Warranty on your CRYONiQ product. Learn More
    Extended Warranty for cryotherapy products
    Extended WarrantySelectDetails

    Minimum
    Recommended

    15 m2   |   160 sqft
    25 m2   |   270 sqft

    Minimum
    Recommended

    20 m2   |   200 sqft
    25 m2   |   270 sqft

    Standard Tank (Dewar)

    *Two dewar vessels are included with the non-pressurized system.

    50 L (Non-Pressurized)

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    4 to 7 Liters*

    Max 4000W; Session 1000W

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    Low capacity tanks

    Standard capacity tanks

    High capacity tanks

    Optimum Pressure

    *Pressurized tanks are not included.

    70 L, 160 L

    180 L, 240 L, 320 L, 350 L

    500 L, 750 L, 1000 L

    1,5 to 2,5 BAR  |  22 to 37 psi

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    5 to 8 Liters*

    Max 4000W; Session 1000W;

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    SystemsPressurized | Non-Pressurized

    Pressurized system

    Non-Pressurized system

    PRESSURIZED

    Non-PRESSURIZED

    Description

    The CRYO XC™ Pressurized system uses pressurized tanks and vessels for the storage and supply of liquid nitrogen.

    During operation, liquid nitrogen is supplied into the system under pressure that is maintained inside the storage vessel.

    Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.
     

    The CRYO XC™ Non-Pressurized system uses non-pressurized vessels or dewars for the storage and supply of liquid nitrogen.

    During operation, liquid nitrogen is transferred into the system with the help of pressure created by the cryotherapy unit.

    Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.

    AVAILABILITY

    CRYO XC™ Plus
    CRYO XC™

    CRYO XC™ Plus
    CRYO XC™

    MEDIUM

    The Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

    The Non-Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

    Storage

    Low capacity tanks

    Standard capacity tanks

    High capacity tanks

    Optimum Pressure

    *Pressurized tanks are not included.

    70 L, 160 L

    180 L, 240 L, 320 L, 350 L

    500 L, 750 L, 1000 L

    1,5 to 2,5 BAR  |  22 to 37 psi

    Standard Tank (Dewar)

    *Two dewar vessels are included with the non-pressurized system.

    50 L (Non-Pressurized)

    CONSUMPTION

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    5 to 8 Liters*

    Max 4000W; Session 1000W;

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    4 to 7 Liters*

    Max 4000W; Session 1000W

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    ROOM REQUIREMENTS

    Minimum
    Recommended

    20 m2   |   200 sqft
    25 m2   |   270 sqft

    The pressurized system requires barrier free access to the supply zone. The lightest pressurized vessels/cylinders weigh  approximately 150 Kg/ 330 Lbs when empty.

    The recommended ceiling height is 240 cm / 8 ft

    For more info go to Room Requirements

    Minimum
    Recommended

    15 m2   |   160 sqft
    25 m2   |   270 sqft

    The non-pressurized system allows for easier access from the supply zone to the cryotherapy unit. The tare weight of the dewar vessel is 17 kg / 25 Lbs and 65 Kg / 130 Lbs when full. These vessels can be carried by hand for refills.

    The recommended ceiling height is 240 cm / 8 ft

    For more info go to Room Requirements

    SUITABLE FOR

    High capacity & high footfall locations. Wellness/Recovery centers, sports organizations, fitness centers, training facilities, rehabilitation facilities, medical facilities/clinics

    Cryotherapy startups, wellness/recovery centers, spas, sports organizations, fitness centers, training facilities, beauty centers, home & private use, exclusive social clubs

    APPROVAL

    The Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

    The Non-Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

    1

    Customer selects Products, Options & Services¹

    • All new customized equipment is made-to-order.
    • Our Existing Inventory offers new stock equipment.
    2

    CRYONiQ confirms acceptance and verifies selection

    3

    CRYONiQ prepares a Price Quote

    • According to the customers selection of items.
    • Payment terms may vary for select territories and products.
    4

    Customer selects form of financing ²

    • The Customer must select their preferred payment method
    • The Customer provides billing details
    • Financing Options are available.
    5

    CRYONiQ prepares Equipment Order Agreement (EOA)

    • The EOA includes the Equipment Configuration and Terms of Purchase.

    6

    CRYONiQ issues an invoice for selected items.

    • A 50% non-refundable deposit is required to validate an order for made-to-order equipment.
    • A 100% deposit is required to validate an order for Pre-Owned Equipment.
    7

    Production & Lead Time

    • A signed Equipment Order Agreement and Deposit are required to begin production
    • Production takes 4 to 8 weeks upon receiving a valid order
    • Expedited delivery may be available in some cases for a fee.
    • Due to supply chain issues, it may be difficult to guarantee an exact delivery date, unless secured sufficiently in advance.
    • We do not offer any compensation for logistics delays.
    8

    Cancellation of Order⁵

    • Can be made within 3 days of submitted order at no cost except accrued transfer charges.
    9

    Preparation for Delivery, Install and training

    10

    Final payment is due before shipping

    • Final Payment is due before the ordered product(s) is shipped. Exceptions may apply.
    11

    Transfer of Ownership

    • CRYONiQ shall retain title to the delivered goods until fulfilment of all claims under the supply contract.

    ¹ Items selected from the Inventory and Pre-Owned inventory may carry different Terms of Purchase than products made-to-order..
    ² Payment options & terms may vary for leases, rentals and other financing products.
    ³ Payments must be made in the following currencies USD - United States. EUR - European Union ; GBP - United Kingdom; EUR - Rest of World; Exceptions may apply
    ⁴ In case of cancellation after 3 work days, owing to the made-to-order nature of the product, CRYONIQ reserves the right to retain the received deposit in full. Any return and the extent of such return is made at the sole discretion of CRYONiQ.
    ⁵ The listed order and payment terms apply to the CRYO XC™ Plus and CRYO XC™. The order and payment terms for other products can be requested individually.

    CRYO XC™ Plus & CRYO XC™

    Model features

    Cryo XCTM PlusCryo XCTM
    MODELS Cryo XCTM Cryo XCTM Plus
    Description
    The CRYO XC™ is CRYONiQ's best-seller. Designed to offer a balanced cryotherapy session and maximum exposure to extreme temperatures.
    The CRYO XC™ Plus is CRYONiQ's flagship cryotherapy chamber which offers an enhanced cryotherapy experience for clients and operators with additional safety and design features.
    Features
    21,5" Touchscreen - Control Panel
    15" Multimedia/Info Screen
    Thermal Contrast Cryotherapy 
    Adaptable Orientation
    Lift
    Deflectors
    Active Drying System
    Session Tracker
    Remote Diagnostics
    Safety Relief Vent
    Exhaust Fan
    Oxygen Monitoring
    Door Sensor
    Humidity Tracking
    Pressure Tracking
    Tremor Emergency Stop
    Heart Rate Monitor

    Systems

    Pressurized System
    Available
    Compare
    Available
    Compare
    Non-Pressurized System
    Available
    Compare
    Available
    Compare

    SESSION TEMPERATURE (Exclusions Apply)

    Temperature Range (Recommended)
    170°F to -200°F
    -110°C to -140°C
    -170°F to -200°F
    -110°C to -140°C
    Temperature Range (Expanded)
    -170°F to -240°F
    -110°C to -160°C
    -170°F to -240°F
    -110°C to -160°C

    STORAGE TANKS

    Pressurized System
    Tanks not included
    Tanks not included
    Non-Pressurized System
    2x 50 liter vessel included
    2x 50 liter vessel included

    LN2 CONSUMPTION 

    Pressurized System
    5 - 8 liters (LN2)
    5 - 8 liters (LN2)
    Non-Pressurized System
    4 - 7 liters (LN2)
    4 - 7 liters (LN2)
    Precool
    2 - 4 Liters (LN2)
    2 - 4 Liters (LN2)

    ELECTRICAL SPECIFICATION

    Outlet Voltage
    230V
    230V
    Frequency
    50 Hz
    50 Hz
    Amperes (Amps)
    min. 16 A
    min. 16 A
    Power Usage
    Max: 4000W
    Idle: 140W
    Session: 1000W
    Drying: 3400W
    Max: 4000W
    Idle: 140W
    Session: 1000W
    Drying: 3400W

    Certification

    CE Mark
    FDA 513g Non-Medical Device

    LEAD TIME

    New & Made-To-Order
    4 to 6 weeks from valid order
    4 to 6 weeks from valid order
    Existing Inventory | Stock Items
    1 to 2 weeks from valid order
    1 to 2 weeks from valid order
    Pre-Owned Inventory
    1 to 2 weeks from valid order
    1 to 2 weeks from valid order
    Express Delivery
    Faster Delivery of Made-To-Order Equipment
    Faster Delivery of Made-To-Order Equipment

    Warranty

    2 Year Limited Service Warranty
    2 Year Limited Parts Warranty
    3 Year Limited Service Warranty
    Available
    Available
    3 Year Limited Parts Warranty
    Available
    Extended Warranty
    Available
    Available

    SERVICES (Exclusions Apply)

    Door to door delivery
    On-Site Install
    On-Site Operator Training
    24/7 Tech Support
    First LN2 Fill for Operator Training*
    Risk Assessment (Remote)

    PROJECT ASSISTANCE (Exclusions Apply)

    LN2 Supplier Sourcing
    Available
    Available
    Financing Options | Lease Options
    Available
    Available
    Insurance Options
    Available
    Available
    Safety Regulations | Risk Assessment
    Available
    Available
    Operation Guidelines
    Available
    Available



    Your Customized

    Summary

    Cryo XCTM

    CRYO XC™ Cryocabin in anthracite grayCRYO XC™ Plus Cryocabin in blackCRYO XC™ Cryo machine in blueCRYO XC™ Cryotherapy unit in grayCRYO XC™ Cryotherapy unit in white

    Specs & General Terms:

    Standard Lead Time: 4 to 8 weeks
    CRYO XC™ Plus & CRYO XC™ Features
    Order Process & Payment Terms
    Delivery & Packaging

    Selected Options:

    Additional Options:

    Additional Information

    Please provide additional information on your enquiry. By filling out this information, you're helping us improve our services.

    Field | Industry

    Objective

    Interested In

    Product Support

    Request a Custom Quote

    Fill out this form to receive a Custom Quote.

    Thank you for submitting
    your request.

    We will respond to your inquiry shortly.

     

    For quick customer service choose one of the following options:

    Chat Now or call (302) 319 9788

    CRYO XC™ Plus

    WBC Chamber/Cryosauna

    CRYO XC™

    WBC Chamber/Cryosauna

    CRYO LC

    Local Cryotherapy Device

    CRYONIQ LLC | 919 North Market St., Wilmington, DE, 198 01

    PACKAGING & DELIVERY

    AIR/SEA FREIGHT PACKAGING

    CRYO XC™ / CRYO XC™ Plus Pressurized System

    Cabin Crate

    L: 80" x W: 41" x H: 47"
    L: 203 cm x W: 103 cm x H: 118 cm
    Weight: 612 lbs / 278.4 Kg

    Tower Crate

    L: 62 x W: 32 x H: 60"
    L: 158 cm x W: 82 cm x H: 151 cm
    Weight: 544 lbs / 246.5 Kg

    CRYO XC™ / CRYO XC™ Plus Non-Pressurized System

    Cabin Crate

    L: 80" x W: 41" x H: 47"
    L: 203 cm x W: 103 cm x H: 118 cm
    Weight: 612 lbs / 278.4 Kg

    Tower Crate

    L: 62 x W: 32 x H: 60"
    L: 158 cm x W: 82 cm x H: 151 cm
    Weight: 544 lbs / 246.5 Kg

    Storage Vessel Crate (2 vessels)

    L: 40" x W: 40" x H: 23"
    L: 102 cm x W: 101 cm x H: 58 cm
    Weight: 154 lbs / 70 Kg

    *All crates are non-stackable. All crates may however carry a load that does not exceed 66 lbs / 30 Kg.
    *Road Freight does not require Air/Sea Freight packaging

    ROAD FREIGHT PACKAGING (EU & UK)

    CRYO XC™ / CRYO XC™ Plus Pressurized System

    Cabin Crate

    L: 80" x W: 41" x H: 47"
    L: 203 cm x W: 103 cm x H: 118 cm
    Weight: 612 lbs / 278.4 Kg

    Tower Crate

    L: 62 x W: 32 x H: 60"
    L: 158 cm x W: 82 cm x H: 151 cm
    Weight: 544 lbs / 246.5 Kg

    Storage Vessel Crate (2 vessels)

    L: 40" x W: 40" x H: 23"
    L: 102 cm x W: 101 cm x H: 58 cm
    Weight: 154 lbs / 70 Kg

    CRYO XC™ / CRYO XC™ Plus Non-Pressurized System

    Cabin Crate

    L: 80" x W: 41" x H: 47"
    L: 203 cm x W: 103 cm x H: 118 cm
    Weight: 612 lbs / 278.4 Kg

    Tower Crate

    L: 62 x W: 32 x H: 60"
    L: 158 cm x W: 82 cm x H: 151 cm
    Weight: 544 lbs / 246.5 Kg

    Storage Vessel Crate (2 vessels)

    L: 40" x W: 40" x H: 23"
    L: 102 cm x W: 101 cm x H: 58 cm
    Weight: 154 lbs / 70 Kg

    SHIPPING OPTIONS

    Air Freight - Shipping time including the import and customs process is usually between 7 - 15 days
    Sea Freight - Shipping time including the import and customs process is usually between 3 - 6 weeks
    Road Freight - 1 to 4 days

    For express delivery please get in touch with a CRYONiQ representative
    If you wish to arrange delivery with your own forwarder, please inform a CRYONiQ representative.

    GET A QUICK QUOTE

    If you would like to receive a Quick Quote:

    or Call us now+1 302 303 0870

    Select Your Model

    Cryo XCTM

    Select Your System

    Cryo XCTM

    Select Exterior Color

    Cryo XCTM

    Orientation

    Select Interior Color

    Cryo XCTM

    Options

    Cryo XCTM

    Options include a list of products and services that are useful when setting up and running a cryotherapy or recovery spot.

    By selecting an option, you are requesting additional information about the selected item.

    Choose the options that you are interested in learning more about or Skip Step.

    Summary of additional options

    Summary

    Your Details

    Additional Information

    Please provide additional information on your enquiry. By filling out this information, you're helping us improve our services.

    Field | Industry

    Objective

    Interested In

    Product Support

    Fill out this form to receive a Custom Quote.

    Thank you for submitting
    your request.

    We will respond to your inquiry shortly.

     

    For quick customer service choose one of the following options:

    Chat Now or call (302) 319 9788

    CRYONIQ LLC | 919 North Market St., Wilmington, DE, 198 01